UVW Series Error Codes
Main Code 02
Sub Code
Detection
Operation after detection
Valid mode
Display

058

It is detected that the current of the S reel motor is not normal.
AUTO OFF

EJECT
(Emergency EJECT)

Display until pressing any button or until inserting a cassette tape again.
078
It is detected that the current of the T reel motor is not normal.
154
The S reel FG cannot be detected by FG check when inserting a cassette tape.
Removes cassette tape automatically.
-
174
The T reel FG cannot be detected by FG check when inserting a cassette tape.
194
Neither S reel FG nor T reel FG can be detected by FG check when inserting a cassette tape.
255
The S reel FG is detected in threading.
AUTO OFF

EJECT
(Emergency EJECT)

274
The T reel FG cannot be detected in threading.
355
The S reel FG is detected in STOP or STILL mode.
375
The T reel FG is detected in STOP or STILL mode.
395
The S reel FG and T reel FG are detected in STOP or STILL mode.
402
It is detected that the tape does not run at the specified speed in F. FWD or REW mode.
STOP
Error is remedied, then the unit operates normally.
Displays until pressing any button.
403
The Slack of the tape is detected in F. FWD or REW mode.
AUTO OFF

EJECT
(Emergency EJECT)

Display until pressing any button or until inserting a cassette tape again.
454
The S reel FG cannot be detected in F. FWD or REW mode.
474
The T reel FG cannot be detected in F. FWD or REW mode.
494
Neither S reel FG nor T reel FG can be detected in F. FWD or REW mode.
496
It is detected that the rotations of S and T reel are not normal in F. FWD or REW mode.
503
The slack of the tape is detected in SEARCH mode.
554
The S reel FG cannot be detected in SEARCH mode.
574
The T reel FG cannot be detected in SEARCH mode.
594
Neither S reel FG nor T reel FG can be detected in SEARCH mode.
AUTO OFF

EJECT
(Emergency EJECT)

Display until pressing any button or until inserting a cassette tape again.
596
It is detected that the rotations of S and T reel are not normal in SEARCH mode.
603
The slack of the tape is detected in PLAY or REC mode.
654
The S reel FG cannot be detected in PLAY or REC mode.
674
The T reel FG cannot be detected in PLAY or REC mode.
694
Neither S reel FG not T reel FG can be detected in PLAY or REC.
696
It is detected that the rotations of S reel and T reel are not normal in PLAY or REC.
803
The slack of the tape is detected when unthreading.
855
The S reel FG is detected when unthreading.
874
The T reel FG cannot be detected when unthreading.
A55
The S reel FG is detected during removal of a cassette tape.
Until the error is remedied, inhibits inserting a cassette tape.
A75
The T reel FG is detected during removal of a cassette tape.
A95
The S reel FG and T reel FG are detected during removal of cassette tape.

 

Main Code 09
Sub Code
Detection
Operation after detection
Valid mode
Display
028
It is detected that the current of the threading motor is not normal.
AUTO OFF

EJECT
(Emergency EJECT)

Display until pressing any button or until inserting a cassette tape again.
209
When detects full top or end of a tape in the threading state and then performs SHORT FF/SHORT REW, top or end is not released.
Removes cassette tape automatically.
-
221
Threading is not completed within the specified time.
AUTO OFF
EJECT
(Emergency EJECT)
821
Unthreading is not completed within the specified time.

 

Main Code 2X: Mechanical control system problem
Main Code 20
Sub Code
Detection
Operation after detection
Valid mode
Display
018
It is detected that the current of the cassette up/down motor is not normal.
AUTO OFF

EJECT

(Emergency EJECT)

Display until pressing any button or until inserting a cassette tape again.
111
The operation of cassette down is not completed within the specified time. Removes cassette tape automatically.
-
911
The operation of cassette up is not completed within the specified time;.
AUTO OFF
Inhibits all modes.

 

Main Code 21
Sub Code
Detection
Operation after detection
Valid mode
Display
0C8
It is detected that the current of the reel position motor is not normal.
AUTO OFF

EJECT

(Emergency EJECT)

Display until pressing any button or until inserting a cassette tape again.
1C1
The driving of the reel position is not completed within the specified time. Removes cassette tape automatically.
-

 

Main Code 3X : Sensors problem

The sub code of the main code 3X is 000.

Main Code
Detection
Operation after detection
Valid mode
Display
30
Tape-top and tape-end are detected at the same time.
STOP
PLAY, EJECT
Displays until an error is clear up.
31
Tape-top is not released.
STOP
PLAY, FF, EJECT
32
Tape-top is not released.
STOP
PLAY, REW, EJECT
33
The reel position sensor detects the L position and S Position at the same time. Inhibits inserting a cassette tape.  

 

Main code 9X : Communication and interface systems problem
Main Code
Sub Code
Detection
91
125
Interface problem detected between system control and keyboard.
138
Problem detected in the hours meter data EEPROM.
145
Initialization problem detected between system control and servo.
165
Interface problem detected between system control and TBC.
436
Problem detected in servo adjustment data EEPROM.
455
Interface problem detected between main servo and sub servo.
92
000
1/2 VD signal at system control input cannot be detected.
93
000
Servo reference sync signal cannot be detected.
94
000
Servo input sync signal cannot be detected.

 

Main code 06
Sub Code
Detection
Operation after detection
Valid mode
Display
6A7
It is detected that the tape tension is not normal in PLAY or REC mode.
Continues operating in the mode in which the problem is detected. When enters other than PLAY or REC mode, AUTO OFF.

The error is remedied, then the unit operates normally.

In PLAY or REC mode: Continues operating. In other than PLAY or REC mode: STOP. then EJECT.

(Emergency EJECT)

Displays until the error is remedied and pressing any button.

 

Main Code 07
Sub Code
Detection
Operation after detection
Valid mode
Display
042
It is detected that the speed of the capstan is not normal.
STOP
The error is remedied, then the unit operates normally.
Displays until pressing any button.
144
The capstan FG cannot be detected by FG check when inserting a cassette tape.
Removes cassette tape automatically.
-
Display until inserting a cassette tape again.

 

Main Code 08
Sub Code
Detection
Operation after detection
Valid mode
Display
03A

It is detected that the speed of the drum is not normal.

ERROR

DRUM SPEED ERROR

HAS BEEN DETECTED

WAIT UNTIL THIS INDICATION GOES OFF.

RETRY (Once unthreading, then threading again.)
EJECT
Displays until the error is remedied.
032
The drum speed problem is not remedied.
AUTO OFF
EJECT
Displays until inserting a cassette tape again.